Time-averaged simulation of the furnace of a commercial CFB boiler

Juho Peltola, Sirpa Kallio, Harui Yang, Xialong Qiu, Jingji Li

    Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

    Abstract

    A time-averaged simulation approach is applied to a 135 MWe circulating fluidized bed combustor located in Ruzhou, China, in which also measurements were carried out. The simulation results show a vertical solids distribution typical for a CFB. Gas composition profiles show plausible but not fully correct distributions of oxygen and combustion products inside the furnace.
    Original languageEnglish
    Title of host publicationProceedings The 14th International Conference on Fluidization
    Subtitle of host publicationFrom Fundamentals to Products
    EditorsJ.A.M. Kuipers, R.F. Mudde, J.R. van Ommen, N.G. Deen
    PublisherEngineering Conferences International (ECI)
    Pages699-706
    ISBN (Print)978-1-62748-882-2
    Publication statusPublished - 2013
    MoE publication typeA4 Article in a conference publication
    Event14th International conference on fluidization, Fluidization XIV: From fundamentals to products - Noordwijkerhout, Netherlands
    Duration: 26 May 201331 May 2013
    Conference number: 14
    http://dc.engconfintl.org/fluidization_xiv/ (May 26-31, 2013 - NH Conference Centre Leeuwenhorst Noordwijkerhout, The Netherlands)

    Conference

    Conference14th International conference on fluidization, Fluidization XIV
    Abbreviated titleFluidization XIV
    Country/TerritoryNetherlands
    CityNoordwijkerhout
    Period26/05/1331/05/13
    Internet address

    Keywords

    • bubbling fluidized bed
    • simulation
    • CFD
    • time-averaged

    Fingerprint

    Dive into the research topics of 'Time-averaged simulation of the furnace of a commercial CFB boiler'. Together they form a unique fingerprint.