Abstract
A time-averaged simulation approach is applied to a 135
MWe circulating fluidized bed combustor located in
Ruzhou, China, in which also measurements were carried
out. The simulation results show a vertical solids
distribution typical for a CFB. Gas composition profiles
show plausible but not fully correct distributions of
oxygen and combustion products inside the furnace.
| Original language | English |
|---|---|
| Title of host publication | Proceedings The 14th International Conference on Fluidization |
| Subtitle of host publication | From Fundamentals to Products |
| Editors | J.A.M. Kuipers, R.F. Mudde, J.R. van Ommen, N.G. Deen |
| Publisher | Engineering Conferences International (ECI) |
| Pages | 699-706 |
| ISBN (Print) | 978-1-62748-882-2 |
| Publication status | Published - 2013 |
| MoE publication type | A4 Article in a conference publication |
| Event | 14th International conference on fluidization, Fluidization XIV: From fundamentals to products - Noordwijkerhout, Netherlands Duration: 26 May 2013 → 31 May 2013 Conference number: 14 http://dc.engconfintl.org/fluidization_xiv/ (May 26-31, 2013 - NH Conference Centre Leeuwenhorst Noordwijkerhout, The Netherlands) |
Conference
| Conference | 14th International conference on fluidization, Fluidization XIV |
|---|---|
| Abbreviated title | Fluidization XIV |
| Country/Territory | Netherlands |
| City | Noordwijkerhout |
| Period | 26/05/13 → 31/05/13 |
| Internet address |
|
Keywords
- bubbling fluidized bed
- simulation
- CFD
- time-averaged
Fingerprint