Abstract

The transition towards a sustainable future requires the reliable performance of the building’s energy system in order for the building to be energy-resilient. “Energy resilient building in cold climates” is an emerging concept that defines the ability to maintain a minimum level of indoor air temperature and energy performance of the building and minimize the occupant’s health risk during a disruptive event of the grid’s power supply loss in a cold climate. The aim is to introduce an extensive definition of the energy resilience of buildings and apply it in case studies. This article first reviews the progress and provides an overview of the energy-resilient building concept. The review shows that most of the relevant focus is on short-term energy resilience, and the serious gap is related to long-term resilience in the context of cold regions. The article presents a basic definition of energy resilience of buildings, a systematic framework, and indicators for analyzing the energy resilience of buildings. Terms such as active and passive habitability, survivability, and adaptive habitable conditions are defined. The energy resilience indicators are applied on two simulated Finnish case studies, an old building and a new building. By systematic analysis, using the defined indicators and thresholds, the energy resilience performance of the buildings is calculated and compared. Depending on the type of the building, the results show that the robustness period is 11 h and 26 h for the old building and the new building, respectively. The old building failed to provide the habitability conditions. The impact of the event is 8.9 °C, minimum performance (Pmin) is 12.54 °C, and degree of disruption (DoD) is 0.300 for the old building. The speed of collapse (SoC) is 3.75 °C/h, and the speed of recovery (SoR) is 0.64 °C/h. On the other hand, the new building performed better such that the impact of the event is 4 °C, Pmin is 17.5 °C, and DoD is 0.138. The SoC is slow 3.2 °C/h and SoR is fast 0.80 °C/h for the new building. The results provide a pathway for improvements for long-term energy resilience. In conclusion, this work supports society and policy-makers to build a sustainable and resilient society.
Original languageEnglish
Article number1453
JournalBuildings
Volume14
Issue number5
DOIs
Publication statusPublished - 17 May 2024
MoE publication typeA1 Journal article-refereed

Funding

This research was funded by the Research Council of Finland, “Energy Resilience in Buildings in Extreme Cold Weather Conditions in Finland 2022–2025 (FinERB), grant number 348060” and funded by the Research Council of Finland, “Integration of Building Flexibility into Future Energy Systems 2020–2024 (FlexiB), grant number 333364”.

Keywords

  • cold climates
  • definition
  • energy crisis
  • energy resilience of buildings
  • framework
  • indicators
  • long term

Fingerprint

Dive into the research topics of 'Towards Extensive Definition and Planning of Energy Resilience in Buildings in Cold Climate'. Together they form a unique fingerprint.

Cite this