Water flow meter calibration in NMI Laboratory of Finland

Mika Huovinen (Corresponding author), Petri Koponen

Research output: Contribution to conferenceConference PosterScientific

Abstract

Centre for Metrology MIKES has gravimetric national standard and also two closed type devices, named as D500 and D100, for water flow calibrations in Finland. These calibration rigs are based on reference meters. Flow rate in the D500 rig is possible up to 2700 m³/h and it has an electromagnetic reference meters size of DN500 and DN150. The D100 contains Coriolis flow meters as a reference meter and their size are DN50 and DN15. Lowest measurement uncertainty is 0.3% (k = 2) for both rigs. Laser Doppler Velocimetry measurements have been done in the D500 rig to verify the proper flow profiles between the meter under test and the reference meter. This presentation will show in detail the results, the construction and the performance of the calibration rigs.
Original languageEnglish
Publication statusPublished - 2016
Event17th International Flow Measurement Conference, FLOMEKO 2016 - Sydney, Australia
Duration: 26 Sep 201629 Sep 2016

Conference

Conference17th International Flow Measurement Conference, FLOMEKO 2016
Abbreviated titleFLOMEKO 2016
CountryAustralia
CitySydney
Period26/09/1629/09/16

Fingerprint

flowmeter
water flow
calibration
laser
laboratory

Cite this

Huovinen, M., & Koponen, P. (2016). Water flow meter calibration in NMI Laboratory of Finland. Poster session presented at 17th International Flow Measurement Conference, FLOMEKO 2016, Sydney, Australia.
Huovinen, Mika ; Koponen, Petri. / Water flow meter calibration in NMI Laboratory of Finland. Poster session presented at 17th International Flow Measurement Conference, FLOMEKO 2016, Sydney, Australia.
@conference{b3f28dd98ebe4326932a9576f070bd27,
title = "Water flow meter calibration in NMI Laboratory of Finland",
abstract = "Centre for Metrology MIKES has gravimetric national standard and also two closed type devices, named as D500 and D100, for water flow calibrations in Finland. These calibration rigs are based on reference meters. Flow rate in the D500 rig is possible up to 2700 m³/h and it has an electromagnetic reference meters size of DN500 and DN150. The D100 contains Coriolis flow meters as a reference meter and their size are DN50 and DN15. Lowest measurement uncertainty is 0.3{\%} (k = 2) for both rigs. Laser Doppler Velocimetry measurements have been done in the D500 rig to verify the proper flow profiles between the meter under test and the reference meter. This presentation will show in detail the results, the construction and the performance of the calibration rigs.",
author = "Mika Huovinen and Petri Koponen",
year = "2016",
language = "English",
note = "17th International Flow Measurement Conference, FLOMEKO 2016, FLOMEKO 2016 ; Conference date: 26-09-2016 Through 29-09-2016",

}

Huovinen, M & Koponen, P 2016, 'Water flow meter calibration in NMI Laboratory of Finland' 17th International Flow Measurement Conference, FLOMEKO 2016, Sydney, Australia, 26/09/16 - 29/09/16, .

Water flow meter calibration in NMI Laboratory of Finland. / Huovinen, Mika (Corresponding author); Koponen, Petri.

2016. Poster session presented at 17th International Flow Measurement Conference, FLOMEKO 2016, Sydney, Australia.

Research output: Contribution to conferenceConference PosterScientific

TY - CONF

T1 - Water flow meter calibration in NMI Laboratory of Finland

AU - Huovinen, Mika

AU - Koponen, Petri

PY - 2016

Y1 - 2016

N2 - Centre for Metrology MIKES has gravimetric national standard and also two closed type devices, named as D500 and D100, for water flow calibrations in Finland. These calibration rigs are based on reference meters. Flow rate in the D500 rig is possible up to 2700 m³/h and it has an electromagnetic reference meters size of DN500 and DN150. The D100 contains Coriolis flow meters as a reference meter and their size are DN50 and DN15. Lowest measurement uncertainty is 0.3% (k = 2) for both rigs. Laser Doppler Velocimetry measurements have been done in the D500 rig to verify the proper flow profiles between the meter under test and the reference meter. This presentation will show in detail the results, the construction and the performance of the calibration rigs.

AB - Centre for Metrology MIKES has gravimetric national standard and also two closed type devices, named as D500 and D100, for water flow calibrations in Finland. These calibration rigs are based on reference meters. Flow rate in the D500 rig is possible up to 2700 m³/h and it has an electromagnetic reference meters size of DN500 and DN150. The D100 contains Coriolis flow meters as a reference meter and their size are DN50 and DN15. Lowest measurement uncertainty is 0.3% (k = 2) for both rigs. Laser Doppler Velocimetry measurements have been done in the D500 rig to verify the proper flow profiles between the meter under test and the reference meter. This presentation will show in detail the results, the construction and the performance of the calibration rigs.

UR - http://metrology.asn.au/flomeko2016/papers/57da6e3b1c1b8-Water%20Flow%20Meter%20Calibration%20in%20NMI%20Laboratory%20of%20Finland.pdf

M3 - Conference Poster

ER -

Huovinen M, Koponen P. Water flow meter calibration in NMI Laboratory of Finland. 2016. Poster session presented at 17th International Flow Measurement Conference, FLOMEKO 2016, Sydney, Australia.